Matrix Lights

Direct, universal illumination of most surfaces.

Data sheet
(order numbers etc.)
2D drawings
(MX-50, MX-90)
3D drawings
(MX-50, MX-90)
  • Compact design
  • Homogenous light field
  • Universal mounting
  • Rough, metal housing

Princip
  • Matrix lights are supplied in different wavelengths
  • Lighting intensity can be regulated by CM-01Mini universal controller
  • Dark-field and bright-field illumination
  • Homogeneous illumination of most surfaces
  • Illumination of bar and 2D codes
  • Detection of defects and missing parts
  • Intense direct illumination
  • Intense back lighting

Basic electric parameters

Model Voltage Span Nominal Voltage Nominal Current Max. Current Trigger Voltage Trigger Current Input
MX-50W 22-28 V 24 V 230 mA 230 mA 12-28 V 3.5 mA 5.5 W
MX-50B 21-28 V 24 V 220 mA 220 mA 12-28 V 3.5 mA 5.3 W
MX-50G 22-28 V 24 V 220 mA 220 mA 12-28 V 3.5 mA 5.8 W
MX-50R 22-28 V 24 V 190 mA 190 mA 12-28 V 3.5 mA 4.5 W
MX-50IR 19-28 V 24 V 190 mA 190 mA 12-28 V 3.5 mA 4.5 W
MX-90W 19-28 V 24 V 345 mA 350 mA 12-28 V 5.9 mA 8.3 W
MX-90B 19-28 V 24 V 340 mA 350 mA 12-28 V 5.9 mA 8.2 W
MX-90G 18-28 V 24 V 345 mA 350 mA 12-28 V 5.9 mA 8.3 W
MX-90R 22-28 V 24 V 350 mA 360 mA 12-28 V 5.9 mA 8.4 W
MX-90IR 23-26 V 24 V 340 mA 410 mA 12-28 V N/A 8.2 W

Dimensions and weights

Model A Length (mm) B Width (mm) C Height (mm) Active Lighting Area Weight
MX-50... 70 63 26 50x50 mm 188 g
MX-90... 111.8 111.8 22 90x90 mm 291 g

Controller CM-01

Terminal box output “OUT LIGHT T” – Light connection

Terminal +24 V: light positive pole
Terminal PWM: PWM signal
Terminal 0 V: light negative pole

Terminal box input “IN LIGHT T” – Power supply and control signal connection

Terminal +24 V: positive pole of 24 V DC Power Supply
Terminal 0 V: negative pole of 24 V DC Power Supply
Terminal TRIG: Trigger signal from camera, PLC, etc.

Controller cm-01 Controller cm-01 schema